P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools Page | 71
Double click on the transition between bubble 2 and 3. In this entry screen setup the following:
Description: (empty)
Visible: not checked
Transition to 2 when: (empty)
Visible: checked
Transition to 3 when: Wait = 0s
Visible: checked
Double click on the transition between bubble 3 and 4. In this entry screen setup the following:
Description: (empty)
Visible: not checked
Transition to 3 when: (empty)
Visible: checked
Transition to 4 when: Wait = 0s
Visible: checked
Double click on the transition between bubble 4 and 5. In this entry screen setup the following:
Description: (empty)
Visible: not checked
Transition to 4 when: (empty)
Visible: checked
Transition to 5 when: Wait = 0s
Visible: checked
Double click on the transition between bubble 5
and 1. In this entry screen setup the following:
Description: (empty)
Visible: not checked
Transition to 5 when: (empty)
Visible: checked
Transition to 1 when: Wait = 0s
Visible: checked
Your bubble Screen should look like this:
Close the bubble logic screen.
Generate the application output files by pressing, "Compile" and then selecting "Make". Note this operation
prompts you to save your project.
Execute the Program Loader Monitor program by double clicking on the Program Loader Monitor icon in the
c:\Program Files\HCT Products folder.
Click on the "Program Load" button.
Power cycle the DVC5/7/10 (Off and On) and click the blue Load Application button.
Open the file created (.pgm extension) using the Programming Tool.