P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools Page | 52
Output Group Selected as Single Coil High-Side
Name Description Range
Name Set the state Current Target or
Process in percentage of min to max
current
0 = 0 Current, .1% = Min Current,
and 100% = Max Current
0% to 100%
Name.Enable Set the PWM to 0 or enable the
PWM
True [PWM Enabled], False
[PWM = 0]
Name.Short Get the Coil Flag for Short Status Off [Coil Ok], On [Coil Short]
Name.Open Get the Coil Flag for Open Status Off [Coil Ok], On [Coil Open]
Name.Rampup Set the ramp up rate (time to travel
from 0% to 100%)
0.0 to 65.00 s
Name.Rampdown Set the ramp down rate (time to
travel from 100% to 0%)
0.0 to 65.00 s
HSEvenName Set the Bang-bang Coil to On or Off Off, On
HSEven#Name.Short Get the Coil Flag for Short Status Off [Coil Ok], On [Coil Short]
HSEven#Name.Open Get the Coil Flag for Open Status Off [Coil Ok], On [Coil Open]
HSOdd#Name.OpenDisable Set the Disable Coil Open Detection 0 [Enabled], 1 [Disabled]
HSOdd#Name.Short Get the Coil Flag for Short Status Off [Coil Ok], On [Coil Short]
HSOdd#Name.Open Get/Set the Coil Flag for Open
Status
Off [Coil Ok], On [Coil Open]
Name.Cur Current actual * CurGain = amps 0 – 3.5 amps
Name.RampCur Current ramped Currend*CurGain=
amps
0 – 3.5 amps
Name.CurErr Current Error = RampCur – Cur 16 Signed Integer
Name.CurSumErr Current Error accumulated over time 0 – 65535
Name.CurP Current Proportional Term Constant
“P”
0 – 255
Name.CurI Current Proportional Term Constant
“I”
0 – 255
Name.MinCurA Minimum Current Coil A *.001 =
amps
0 – 3.5 amps
Name.MaxCurA Maximum Current Coil A *.001 =
amps
0 – 3.5 amps
Name.Config Configuration Word –Output,
Process, Coil
Output Group Selected as Single Coil Low-Side
Name Description Range
Name
Set the state Current Target or Process in
percentage of min to max current
0 = 0 Current, .1% = Min Current, and
100% = Max Current
0% to 100%
Name.Enable Set the PWM to 0 or enable the PWM True [PWM Enabled],
False [PWM = 0]
Name.Short Get the Coil Flag for Short Status Off [Coil Ok], On [Coil
Short]
Name.Open Get the Coil Flag for Open Status Off [Coil Ok], On [Coil
Open]
Name.Rampup Set the ramp up rate (time to travel from
0% to 100%)
0.0 to 65.00 s
Name.Rampdown Set the ramp down rate (time to travel 0.0 to 65.00 s
Komentáře k této Příručce