Hydraulic Fan System Controller – HFS-3-12v
12
Adjustment Guide: NON-Inverting valve control operation.
Output Characteristics: NON Inverted Valve operation.
I Max 100%
I Max 75%
I Max 50%
90%
PWM
10%
PWM
1200mA ( Max )
0%
PWM
100%
PWM
This graph shows the typical
adjustments for the PWM input
signal
Typical input / output current linearity graph of this controller.
0%
20%
40%
60%
80%
100%
110%
Output Current mA
0% 20% 30% 40% 50% 60% 70% 80% 100%
PWM input %
10% 90%
Typical characteristic of a normal
pressure or flow control valve or
variable piston pump Electro-
hydraulic stroker. This option will
NOT allow ‘fail-to-full-speed’ safety
operation.
It is strongly recommended that the
INVERTED option is used in
conjunction with a reverse operating
pressure control valve to allow
‘fail-to-full-speed’ operation.